Product Category

1805 ER

Datasheet print icon-img

FEATURES

  • High quality Taut Band movement.
  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • Test test leads are supplied as standard accessories for simplified two-wire measuring system.
  • Battery operated.
  • Battery check function.
  • Calibration performed with supplied test leads.

SPECIFICATIONS

Measuring ranges Earth resistance
0-10Ω / 0-100Ω / 0-1000Ω
Earth voltage 0-30 Vac (40-500Hz)
Accuracy Earth resistance ±3% of full scale
Earth voltage ±2.5% of full scale
Measuring system Earth resistance by constant current inverter 820Hz, 2mA approx.
Open circuit indication LED will be unlit
Dimensions 170(L) × 165(W) × 92(D)mm
Weight
(battery included)
Approx. 1000g
Power source 1.5V (AA) × 8
Safety standards EN 61010-1 CAT III 300V
EN 61326-1

Feedback list

Post your feedback
Cart

Login