- Capable of measuring earth resistance and earth voltage.
- 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
- In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.
- Battery operated.
- Battery life indicator.
- Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges | Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) |
---|---|
Accuracy | Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale |
Measuring system | Earth resistance by constant current inverter 820 Hz, 2mA approx. |
Open circuit indication | LED will be unlit |
Dimensions | 175(L) × 85(W) × 75(D)mm |
Weight (battery included) |
Approx. 600g |
Power source | 1.5V (AA) × 8 |
Safety standards | EN 61010-1 CAT IV 30V EN 61326-1 |